Get in Touch Get in Touch
BPP-60 PV Backsheet

BPP-60 PV Backsheet

  • BPP-60 is a lightweight module backsheet made with a PP multilayer fiberglass composite structure and double-sided weather-resistant coatings, offering excellent insulation, structural support, and bonding performance.
  • With a total thickness of 0.7±10%, MD/TD tensile strength ≥300 N/mm², breakdown voltage ≥20 kV, partial discharge voltage ≥1500 VDC, and reflectance ≥75%, it provides high-strength support, reliable insulation, and long-term weather protection for lightweight PV modules.
Get a Free Consultation Get a Free Consultation

Performance Indicators

Test Standard BPP-60

Total Thickness

/ 0.7±10%mm

Colour

/ White/Black

Fluorine Content

/ Fluoropolymer Coating/Fluoropolymer Free

Tensile Strength

MD GB/T 13542.2-2009 ≥300N/mm²
TD GB/T 13542.2-2009 ≥300N/mm²

Heat Shrinkage Rate

MD GB/T 13542.2-2009 0≤MD≤0.8%
TD GB/T 13542.2-2009 0≤MD≤0.8%

Coating Adhesion (grade)

GB/T 9286-1998 grade 0

Bond Strength With EVA /POE (initial)

GB/T 2790-1995 ≥60N/10mm

Interlayer Peel Strength (Initial)

GB/T 2790-1995 ≥4N/10mm

Breakdown Voltage

GB/T 13542.2-2009 ≥20kV

Comparative Tracking Index (CTI)

IEC 60664-1 ≥300V

Partial Discharge Voltage

IEC 60664-1 ≥1500VDC

WVTR

GB/T 26253-2010 ≤1g/m²·d

Reflectivity (400mm-1100nm)

GB/T 2410-2008 ≥70%

Damp Heat Aging Test

IEC 61215-2005 No delamination, no bubbles, Δb≤2

UV Aging

IEC 61215-2005 No delamination, no bubbles, no embrittlement, Δb≤2

Thermal Cycling Test

IEC 61215-2005 No delamination, no bubbles, no embrittlement, Δb≤2

Humidity Freeze Test

IEC 61215-2005 No delamination, no bubbles, no embrittlement, Δb≤2

Boiling Water  Treatment

Visual Inspection GB/T 17748-2008 No delamination, no bubbles, no wrinkling, no peeling, no chalking
Coating Adhesion(Grade) GB/T 9286-1998 Grade 0

Leave Your Message